The Physics Behind
Measuring Excellence.

Invented in the 1970s, BIPM-recognized since 1976. ph-instruments makes it fully industrial for the first time.

Measurement Principle

The Spinning Rotor Gauge

A 4.5mm stainless steel ball is magnetically levitated in a sealed measuring tube and electromagnetically accelerated to 600 revolutions per second. Once spinning, it coasts freely in vacuum.

Gas molecules decelerate the ball at a rate precisely proportional to gas pressure. This deceleration (molecular drag) is measured via external coils — no feedthroughs, no filament. The accommodation coefficient σ deviates less than 1% from ideal — making the VIM-1 a fundamental gauge that does not drift as electronics age.

⚡ Ball accelerated to 600 rps electromagnetically
📡 Deceleration measured contactlessly — no feedthroughs
📐 Pressure from first principles — absolute result
🌡️ Temperature continuously compensated by integrated sensor
 
Timeline
Theory: 1970s · Prototype: 1976 · Commercial: 1981 · SRG Transducer: 2019 · High-Temp SRG 100°C: 2025 (world-first)

In Motion

How Molecular Drag
Becomes Pressure.

Gas molecules adsorb onto the polished steel surface, transfer their kinetic energy, and desorb in a thermalized random direction.The collective momentum transfer slows the ball — and the rate of deceleration is directly proportional to gas pressure. No filament. No ionization. Pure physics.

[01]  Ball spins freely at 600 rps in vacuum
[02]  Gas molecules collide and adsorb (orange flash)
[03]  Energy exchange — molecules desorb thermally
[04]  Cumulative momentum transfer slows the ball

Head-to-Head

SRG vs. Capacitive Manometer vs. Ion Gauge

Three high-vacuum measurement principles, each with its own physics. 

The SRG is the only one that delivers absolute accuracy with no drift, no filament, and no membrane sensitivity across the critical 10⁻⁴ to 10⁻⁶ mbar range.

ParameterSpinning Rotor Gauge (SRG)Capacitive ManometerIon Gauge (Bayard-Alpert)
Measurement PrincipleMolecular viscous drag — absoluteMembrane deflection — absoluteIonization current — relative
Pressure Range✓ 10⁻² to 10⁻⁷ mbar~ 10³ to 10⁻⁴ mbar (limited)10⁻³ to 10⁻¹⁰ mbar
Accuracy (calibrated)✓ ±1% of reading✓ ±0.25–0.5% of reading✗ ±15–30% after drift
Annual Drift✓ <1.5% / year~ 1–5% / year (membrane)✗ 30–40% / year (MKS data)
Gas Independence✓ Compensable (√M)✓ Fully gas-independent✗ Multi-point per gas
Filament✓ None✓ None✗ Required — burns out, degasses
Coating Sensitivity✓ Zero — only ball diameter matters✗ High — coats membrane, shifts zero✗ High — shifts ionization rate
Membrane Bending / Zero Drift✓ Not applicable — no membrane✗ Yes — temperature-sensitive✓ Not applicable
Sensor Lifetime✓ >10 years (some 30+ years)~ 3–5 years typical✗ 2 weeks–6 months (HC implant)
Heated Operation Required✓ No — room temp✗ Yes — typically 45–200°C✓ No (filament heated, not body)
Electrical Feedthroughs✓ None — purely electromagnetic✗ Required — capacitor sensing✗ Required — potential leak path
Influences Vacuum✓ No — fully passive✓ No — passive✗ Yes — gettering, ionization, outgassing
Hydrogen Measurement✓ Yes — direct✓ Yes — gas-independent✗ Interference
Corrosive Gas Tolerance✓ Yes (BF₃, PH₃, etc.)~ Limited — Inconel/Hastelloy needed✗ Filament attacked
ARC / Plasma Sensitivity✓ Immune✓ Immune✗ Highly sensitive — filament damage
Calibration Standard✓ BIPM primary transfer standardReference — laboratory calibrationRelative — needs external reference

Bottom Line

Capacitive manometers excel above 10⁻⁴ mbar with high precision — but lose performance in the high-vacuum regime due to membrane bending and zero drift.

Ion gauges reach into UHV but drift heavily, suffer from filament aging, and cannot measure hydrogen or process-aggressive gases reliably.

The SRG fills the gap: in the 10⁻⁴ to 10⁻⁶ mbar range — where most semiconductor and cryogenic applications operate — no other technology matches its accuracy, drift stability, and lifetime.